Dry Emission Reduction
Case Studies
Duke Energy – New Albany Plant
- Plant located in New Albany, Mississippi, Contract awarded Dec. 1998, Start-up April 1999
- Originally constructed for Enron International by TTS
- Unit Relocations – Six (6) GE Frame 7B units from Korea to the US
- Units initially operating on liquid fuel, firing at 1865°F

- Units converted to gas fuel low NOX combustors, increased firing temperature to 1965-2020°F
- Upgrades included: Fuel control system design and install, TTS Control System, and low NOX system control sequencing
- Units operated below 15 ppm NOX

Doyle LLC
- Plant located in Monroe, Georgia, Contract Awarded mid-1999, Start-up mid-2000
- Originally constructed for Enron International by TTS
- Unit Relocations – three (3) GE Frame 7Bs: one (1) from North America, two (2) from Korea
- Units initially operating on liquid fuel, firing at 1865°F
- Units converted to gas fuel low NOX combustors, increased firing temperature to 1965-2020°F
- Upgrades included: Fuel control system design and installation, TTS Control System, and low NOX system control sequencing
- Units operated below 15 ppm NOX
Desert Power Project
- Plant relocated to Rowley, Utah
- Owned by DQ holdings LLC
- Unit Relocations – Two (2) Hitachi Frame 6B machines to US
- Units initially operating on liquid fuel with water injection
- Power conversion from 50 Hz to 60 Hz
- Units converted to gas fuel low NOX combustors
- TTS took over project and converted the units to DER
- Units run SPS DER systems including combustion hardware
- Units achieved below 25 ppm NOX


El Paso Eagle Point Cogen
- Located in Smithville, New Jersey
- Owned by El Paso Corporation
- Two (2) 7EA units initially Multi-Nozzle Quiet Combustor dual fuel system with steam injection for NOx reduction
- Units converted to SPS DER dual fuel system with water injection for liquid NOx reduction.
- First non-OEM conversions with dual fuel water injection & bleed heat manifolds for 60% turndown
- First non-OEM 7EA Dry Low NOX conversions
- Units guaranteed for 9 ppm NOX 15 ppm CO and beat these targets
- Units are uprated to 2035˚F firing temperature